using Modbus.Device;
using System;
using System.Configuration;
using System.Net.Sockets;
using System.Windows;
using System.Windows.Controls;
using System.Windows.Input;
using System.Windows.Threading;
using .Data;
namespace
{
public partial class ParameterSettingsWindow : Window
{
private MainWindow _mainWindow;
private MainWindow2 _mainWindow2;
private MainWindow3 _mainWindow3;
private MainWindow4 _mainWindow4;
private readonly DispatcherTimer _readTimer;
private bool _isManualInput = false; // 手动输入标记true=输入中暂停读取false=正常读取
private TcpClient _tcpClient => ModbusResourceManager.Instance.TcpClient;
private IModbusMaster _modbusMaster => ModbusResourceManager.Instance.ModbusMaster;
Function ma;
DataChange c = new DataChange();
public ParameterSettingsWindow()
{
InitializeComponent();
LoadCurrentSettings();
_readTimer = InitDispatcherTimer();
}
private DispatcherTimer InitDispatcherTimer()
{
var timer = new DispatcherTimer
{
Interval = TimeSpan.FromMilliseconds(500)
};
timer.Tick += async (s, e) =>
{
if (!_isManualInput && _modbusMaster != null)
{
try
{
await ReadAllPlcDataAsync();
}
catch { }
}
};
return timer;
}
private async System.Threading.Tasks.Task ReadAllPlcDataAsync()
{
if (_tcpClient == null || !_tcpClient.Connected || _modbusMaster == null)
{
return;
}
// 仅在非手动输入时读取设置地址(避免覆盖输入)
if (!_isManualInput)
{
await ReadAddr262DataAsync();
//await System.Threading.Tasks.Task.Delay(50);
//await ReadAddr404DataAsync();
//await System.Threading.Tasks.Task.Delay(50);
//await ReadAddr406DataAsync();
//await System.Threading.Tasks.Task.Delay(50);
//await ReadAddr130DataAsync();
}
}
// 加载当前设置
private void LoadCurrentSettings()
{
// 这里可以连接实际的数据源来加载当前设置
// 目前使用默认值
}
// 保存按钮点击事件
//private void SaveButton_Click(object sender, RoutedEventArgs e)
//{
// try
// {
// // 验证并保存所有参数
// if (ValidateParameters())
// {
// SaveParameters();
// MessageBox.Show("参数保存成功!", "提示", MessageBoxButton.OK, MessageBoxImage.Information);
// }
// }
// catch (Exception ex)
// {
// MessageBox.Show($"保存参数时出错:{ex.Message}", "错误", MessageBoxButton.OK, MessageBoxImage.Error);
// }
//}
// 重置按钮点击事件
private void ResetButton_Click(object sender, RoutedEventArgs e)
{
var result = MessageBox.Show("确定要重置所有参数吗?", "确认重置",
MessageBoxButton.YesNo, MessageBoxImage.Question);
if (result == MessageBoxResult.Yes)
{
ResetToDefaults();
}
}
// 返回按钮点击事件
private void ReturnButton_Click(object sender, RoutedEventArgs e)
{
SwitchWindow(ref _mainWindow, () => new MainWindow());
}
private void SwitchWindow<T>(ref T windowInstance, Func<T> createFunc) where T : Window, new()
{
// 1. 停止当前窗口的定时器(不释放资源)
_readTimer?.Stop();
// 2. 检查资源是否可用(添加重连机制)
if (_tcpClient == null || !_tcpClient.Connected || _modbusMaster == null)
{
// 尝试重新连接
bool reconnectSuccess = TryReconnect();
if (!reconnectSuccess)
{
MessageBox.Show("TCP连接已断开请重新连接", "提示");
return;
}
}
// 3. 复用窗口实例:不存在则创建,存在则激活
if (windowInstance == null)
{
windowInstance = createFunc();
// 添加窗口关闭事件处理
windowInstance.Closed += (s, args) =>
{
WindowNavigationHelper.RestoreWindow(this, () => _readTimer?.Start());
};
}
else
{
WindowNavigationHelper.ShowWithoutWhiteFlash(this, windowInstance);
return;
}
WindowNavigationHelper.ShowWithoutWhiteFlash(this, windowInstance);
}
// 添加重连方法
private bool TryReconnect()
{
try
{
string plcIp = "192.168.1.10";
bool initSuccess = Data.ModbusResourceManager.Instance.Init(plcIp, 502);
if (initSuccess)
{
ma = new Function(_modbusMaster);
return true;
}
}
catch (Exception ex)
{
ShowErrorMsg($"重新连接失败:{ex.Message}");
}
return false;
}
private async System.Threading.Tasks.Task ReadAddr262DataAsync()
{
try
{
ushort[] registers3 = await System.Threading.Tasks.Task.Run(() =>
_modbusMaster?.ReadHoldingRegisters(1, 1428, 2)
);
if (registers3 != null)
{
float addr406Value = c.UshortToFloat(registers3[1], registers3[0]);
Dispatcher.Invoke(() => txtPressureDiffCoefficient.Text = addr406Value.ToString("F2"));
}
ushort[] registers4 = await System.Threading.Tasks.Task.Run(() =>
_modbusMaster?.ReadHoldingRegisters(1, 484, 2)
);
if (registers4 != null)
{
float addr406Value = c.UshortToFloat(registers4[1], registers4[0]);
Dispatcher.Invoke(() => txtUpperLimit.Text = addr406Value.ToString("F2"));
}
ushort[] registers5 = await System.Threading.Tasks.Task.Run(() =>
_modbusMaster?.ReadHoldingRegisters(1, 482, 2)
);
if (registers5 != null)
{
float addr406Value = c.UshortToFloat(registers5[1], registers5[0]);
Dispatcher.Invoke(() => txtLowerLimit.Text = addr406Value.ToString("F2"));
}
ushort[] registers6 = await System.Threading.Tasks.Task.Run(() =>
_modbusMaster?.ReadHoldingRegisters(1, 490, 2)
);
if (registers6 != null)
{
float addr406Value = c.UshortToFloat(registers6[1], registers6[0]);
Dispatcher.Invoke(() => txtLargeFlowCoefficient2.Text = addr406Value.ToString("F2"));
}
ushort[] registers7 = await System.Threading.Tasks.Task.Run(() =>
_modbusMaster?.ReadHoldingRegisters(1, 492, 2)
);
if (registers7 != null)
{
float addr406Value = c.UshortToFloat(registers7[1], registers7[0]);
Dispatcher.Invoke(() => txtSmallFlowCoefficient2.Text = addr406Value.ToString("F2"));
}
ushort[] registers8 = await System.Threading.Tasks.Task.Run(() =>
_modbusMaster?.ReadHoldingRegisters(1, 1328, 2)
);
if (registers8 != null)
{
float addr406Value = c.UshortToFloat(registers8[1], registers8[0]);
Dispatcher.Invoke(() => txtLargeFlowCoefficient.Text = addr406Value.ToString("F2"));
}
ushort[] registers9 = await System.Threading.Tasks.Task.Run(() =>
_modbusMaster?.ReadHoldingRegisters(1, 1378, 2)
);
if (registers9 != null)
{
float addr406Value = c.UshortToFloat(registers9[1], registers9[0]);
Dispatcher.Invoke(() => txtSmallFlowCoefficient.Text = addr406Value.ToString("F2"));
}
ushort[] registers10 = await System.Threading.Tasks.Task.Run(() =>
_modbusMaster?.ReadHoldingRegisters(1, 308, 2)
);
if (registers10 != null)
{
float addr406Value = c.UshortToFloat(registers10[1], registers10[0]);
Dispatcher.Invoke(() => txtQualityThreshold.Text = addr406Value.ToString("F2"));
}
ushort[] registers11 = await System.Threading.Tasks.Task.Run(() =>
_modbusMaster?.ReadHoldingRegisters(1, 330, 2)
);
if (registers11 != null)
{
int addr406Value = registers11[0];
Dispatcher.Invoke(() => txtExhaustTime.Text = addr406Value.ToString("F0"));
}
ushort[] registers12 = await System.Threading.Tasks.Task.Run(() =>
_modbusMaster?.ReadHoldingRegisters(1, 326, 1)
);
if (registers12 != null)
{
//float addr406Value = c.UshortToFloat(registers12[1], registers12[0]);
int addr406Value = registers12[0];
Dispatcher.Invoke(() => txtPositiveError.Text = addr406Value.ToString("F0"));
}
ushort[] registers13 = await System.Threading.Tasks.Task.Run(() =>
_modbusMaster?.ReadHoldingRegisters(1, 316, 1)
);
if (registers13 != null)
{
//float addr406Value = c.UshortToFloat(registers13[1], registers13[0]);
float addr406Value = registers13[0];
Dispatcher.Invoke(() => txtNegativeError.Text = addr406Value.ToString("F0"));
}
ushort[] registers14 = await System.Threading.Tasks.Task.Run(() =>
_modbusMaster?.ReadHoldingRegisters(1, 324, 1)
);
if (registers14 != null)
{
int addr406Value = registers14[0];
Dispatcher.Invoke(() => txtPositivePIDTime.Text = addr406Value.ToString("F0"));
}
ushort[] registers15 = await System.Threading.Tasks.Task.Run(() =>
_modbusMaster?.ReadHoldingRegisters(1, 314, 1)
);
if (registers15 != null)
{
int addr406Value = registers15[0];
Dispatcher.Invoke(() => txtNegativePIDTime.Text = addr406Value.ToString("F0"));
}
ushort[] registers16 = await System.Threading.Tasks.Task.Run(() =>
_modbusMaster?.ReadHoldingRegisters(1, 328, 1)
);
if (registers16 != null)
{
int addr406Value = registers16[0];
Dispatcher.Invoke(() => txtPositiveDelay.Text = addr406Value.ToString("F0"));
}
ushort[] registers17 = await System.Threading.Tasks.Task.Run(() =>
_modbusMaster?.ReadHoldingRegisters(1, 318, 1)
);
if (registers17 != null)
{
int addr406Value = registers17[0];
Dispatcher.Invoke(() => txtNegativeDelay.Text = addr406Value.ToString("F0"));
}
ushort[] registers18 = await System.Threading.Tasks.Task.Run(() =>
_modbusMaster?.ReadHoldingRegisters(1, 292, 2)
);
if (registers18 != null)
{
float addr406Value = c.UshortToFloat(registers18[1], registers18[0]);
Dispatcher.Invoke(() => txtPositivePIDPressure.Text = addr406Value.ToString("F2"));
}
ushort[] registers19 = await System.Threading.Tasks.Task.Run(() =>
_modbusMaster?.ReadHoldingRegisters(1, 290, 2)
);
if (registers19 != null)
{
float addr406Value = c.UshortToFloat(registers19[1], registers19[0]);
Dispatcher.Invoke(() => txtNegativePIDPressure.Text = addr406Value.ToString("F2"));
}
ushort[] registers20 = await System.Threading.Tasks.Task.Run(() =>
_modbusMaster?.ReadHoldingRegisters(1, 1430, 2)
);
if (registers20 != null)
{
float addr406Value = c.UshortToFloat(registers20[1], registers20[0]);
Dispatcher.Invoke(() => pressureDiff.Text = addr406Value.ToString("F2"));
}
ushort[] registers21 = await System.Threading.Tasks.Task.Run(() =>
_modbusMaster?.ReadHoldingRegisters(1, 1330, 2)
);
if (registers21 != null)
{
float addr406Value = c.UshortToFloat(registers21[1], registers21[0]);
Dispatcher.Invoke(() => flow.Text = addr406Value.ToString("F2"));
}
// ushort[] registers22 = await System.Threading.Tasks.Task.Run(() =>
//_modbusMaster?.ReadHoldingRegisters(1, 390, 2)
//);
// if (registers22 != null)
// {
// int addr406Value = registers22[0];
// Dispatcher.Invoke(() => setsound.Text = addr406Value.ToString("F0"));
// }
}
catch (Exception ex)
{
//ShowErrorMsg($"读取地址406失败{ex.Message}");
}
}
private void ShowErrorMsg(string msg)
{
Dispatcher.Invoke(() =>
{
MessageBox.Show(msg, "错误", MessageBoxButton.OK, MessageBoxImage.Error);
});
}
private void Window_Loaded(object sender, RoutedEventArgs e)
{
string plcIp = "192.168.1.10";
bool initSuccess = Data.ModbusResourceManager.Instance.Init(plcIp, 502);
if (!initSuccess)
{
MessageBox.Show("连接Modbus服务器失败", "错误");
this.Close();
return;
}
// 检查连接状态
if (_tcpClient == null || !_tcpClient.Connected)
{
MessageBox.Show("Modbus连接异常", "错误");
this.Close();
return;
}
ma = new Function(_modbusMaster);
//ma.BtnClickFunctionForNew(Function.ButtonType.切换型, 64);
System.Threading.Tasks.Task.Delay(50);
_readTimer.Start();
}
private void Window_Closing(object sender, System.ComponentModel.CancelEventArgs e)
{
// 停止定时器
_readTimer?.Stop();
// 停止ViewModel的定时器
if (DataContext is MainViewModel viewModel)
{
viewModel.StopTimer();
}
// 释放Modbus资源
ModbusResourceManager.Instance?.Dispose();
// 延后到当前窗口完成关闭后再统一关停,避免关闭重入。
AppShutdownCoordinator.RequestShutdown();
}
private void Window_Closed(object sender, EventArgs e)
{
// 由应用级关停统一处理其他窗口,避免关闭链路重入。
}
// 重置为默认值
private void ResetToDefaults()
{
txtPressureDiffCoefficient.Text = "0.00";
txtUpperLimit.Text = "0.0";
txtLowerLimit.Text = "0.0";
txtLargeFlowCoefficient.Text = "0.00";
txtSmallFlowCoefficient.Text = "0.00";
//txtYear.Text = "0";
//txtMonth.Text = "0";
//txtDay.Text = "0";
//txtHour.Text = "0";
//txtMinute.Text = "0";
//txtSecond.Text = "0";
txtQualityThreshold.Text = "0.00";
txtExhaustTime.Text = "0";
txtPositiveError.Text = "0";
txtNegativeError.Text = "0";
txtPositivePIDTime.Text = "0";
txtNegativePIDTime.Text = "0";
txtPositiveDelay.Text = "0";
txtNegativeDelay.Text = "0";
txtPositivePIDPressure.Text = "0.00";
txtNegativePIDPressure.Text = "0.00";
}
private void txtPressureDiffCoefficient_TouchDown(object sender, System.Windows.Input.TouchEventArgs e)
{
ma.WriteToPLCForNew(txtPressureDiffCoefficient.Text.Trim(), 1428, Function.DataType.);
System.Threading.Tasks.Task.Delay(50);
_isManualInput = false; // 写入后恢复读取
t0.Focus();
}
private void Button_Click(object sender, RoutedEventArgs e)
{
ma.BtnClickFunctionForNew(Function.ButtonType., 1301);
}
private void txtLargeFlowCoefficient2_GotFocus(object sender, RoutedEventArgs e)
{
ma.WriteToPLCForNew(txtLargeFlowCoefficient2.Text.Trim(), 490, Function.DataType.);
System.Threading.Tasks.Task.Delay(50);
_isManualInput = false; // 写入后恢复读取
t0.Focus();
}
private void txtSmallFlowCoefficient2_GotFocus(object sender, RoutedEventArgs e)
{
ma.WriteToPLCForNew(txtSmallFlowCoefficient2.Text.Trim(), 492, Function.DataType.);
System.Threading.Tasks.Task.Delay(50);
_isManualInput = false; // 写入后恢复读取
t0.Focus();
}
private void txtPressureDiffCoefficient_GotFocus(object sender, RoutedEventArgs e)
{
ma.WriteToPLCForNew(txtPressureDiffCoefficient.Text.Trim(), 1428, Function.DataType.);
System.Threading.Tasks.Task.Delay(50);
_isManualInput = false; // 写入后恢复读取
t0.Focus();
}
private void txtUpperLimit_GotFocus(object sender, RoutedEventArgs e)
{
ma.WriteToPLCForNew(txtUpperLimit.Text.Trim(), 484, Function.DataType.);
System.Threading.Tasks.Task.Delay(50);
_isManualInput = false; // 写入后恢复读取
t0.Focus();
}
private void txtLowerLimit_GotFocus(object sender, RoutedEventArgs e)
{
ma.WriteToPLCForNew(txtLowerLimit.Text.Trim(), 482, Function.DataType.);
System.Threading.Tasks.Task.Delay(50);
_isManualInput = false; // 写入后恢复读取
t0.Focus();
}
private void txtLargeFlowCoefficient_GotFocus(object sender, RoutedEventArgs e)
{
ma.WriteToPLCForNew(txtLargeFlowCoefficient.Text.Trim(), 1328, Function.DataType.);
System.Threading.Tasks.Task.Delay(50);
_isManualInput = false; // 写入后恢复读取
t0.Focus();
}
private void txtSmallFlowCoefficient_GotFocus(object sender, RoutedEventArgs e)
{
ma.WriteToPLCForNew(txtSmallFlowCoefficient.Text.Trim(), 1378, Function.DataType.);
System.Threading.Tasks.Task.Delay(50);
_isManualInput = false; // 写入后恢复读取
t0.Focus();
}
private void Button_Click_1(object sender, RoutedEventArgs e)
{
ma.BtnClickFunctionForNew(Function.ButtonType., 1300);
}
private void txtQualityThreshold_GotFocus(object sender, RoutedEventArgs e)
{
ma.WriteToPLCForNew(txtQualityThreshold.Text.Trim(), 308, Function.DataType.);
System.Threading.Tasks.Task.Delay(50);
_isManualInput = false; // 写入后恢复读取
t0.Focus();
}
private void txtExhaustTime_GotFocus(object sender, RoutedEventArgs e)
{
ma.WriteToPLCForNew(txtExhaustTime.Text.Trim(), 330, Function.DataType.);
System.Threading.Tasks.Task.Delay(50);
_isManualInput = false; // 写入后恢复读取
t0.Focus();
}
private void txtPositiveError_GotFocus(object sender, RoutedEventArgs e)
{
ma.WriteToPLCForNew(txtPositiveError.Text.Trim(), 326, Function.DataType.);
System.Threading.Tasks.Task.Delay(50);
_isManualInput = false; // 写入后恢复读取
t0.Focus();
}
//private async void Button_Click_2(object sender, RoutedEventArgs e)
//{
// ma.BtnClickFunctionForNew(Function.ButtonType.切换型, 24);
// bool[] b = await _modbusMaster.ReadCoilsAsync(1, 24, 1);
// if (b != null && b.Length > 0)
// {
// if (!b[0])
// {
// closesound.Content = "关闭语音";
// }
// else
// {
// closesound.Content = "开启语音";
// }
// }
//}
private void Button_Click_3(object sender, RoutedEventArgs e)
{
ma.BtnClickFunctionForNew(Function.ButtonType., 25);
}
//private void setsound_GotFocus(object sender, RoutedEventArgs e)
//{
// ma.WriteToPLCForNew(setsound.Text.Trim(), 390, Function.DataType.整形);
// System.Threading.Tasks.Task.Delay(50);
// _isManualInput = false; // 写入后恢复读取
// t0.Focus();
//}
private void txtNegativeError_GotFocus(object sender, RoutedEventArgs e)
{
ma.WriteToPLCForNew(txtNegativeError.Text.Trim(), 316, Function.DataType.);
System.Threading.Tasks.Task.Delay(50);
_isManualInput = false; // 写入后恢复读取
t0.Focus();
}
private void txtPositivePIDTime_GotFocus(object sender, RoutedEventArgs e)
{
ma.WriteToPLCForNew(txtPositivePIDTime.Text.Trim(), 324, Function.DataType.);
System.Threading.Tasks.Task.Delay(50);
_isManualInput = false; // 写入后恢复读取
t0.Focus();
}
private void txtNegativePIDTime_GotFocus(object sender, RoutedEventArgs e)
{
ma.WriteToPLCForNew(txtNegativePIDTime.Text.Trim(), 314, Function.DataType.);
System.Threading.Tasks.Task.Delay(50);
_isManualInput = false; // 写入后恢复读取
t0.Focus();
}
private void txtPositiveDelay_GotFocus(object sender, RoutedEventArgs e)
{
ma.WriteToPLCForNew(txtPositiveDelay.Text.Trim(), 328, Function.DataType.);
System.Threading.Tasks.Task.Delay(50);
_isManualInput = false; // 写入后恢复读取
t0.Focus();
}
private void txtNegativeDelay_GotFocus(object sender, RoutedEventArgs e)
{
ma.WriteToPLCForNew(txtNegativeDelay.Text.Trim(), 318, Function.DataType.);
System.Threading.Tasks.Task.Delay(50);
_isManualInput = false; // 写入后恢复读取
t0.Focus();
}
private void txtPositivePIDPressure_GotFocus(object sender, RoutedEventArgs e)
{
ma.WriteToPLCForNew(txtPositivePIDPressure.Text.Trim(), 292, Function.DataType.);
System.Threading.Tasks.Task.Delay(50);
_isManualInput = false; // 写入后恢复读取
t0.Focus();
}
private void txtNegativePIDPressure_GotFocus(object sender, RoutedEventArgs e)
{
ma.WriteToPLCForNew(txtNegativePIDPressure.Text.Trim(), 290, Function.DataType.);
System.Threading.Tasks.Task.Delay(50);
_isManualInput = false; // 写入后恢复读取
t0.Focus();
}
//private void pressureDiff2_GotFocus(object sender, RoutedEventArgs e)
//{
//}
/// <summary>
/// 保存 AppSettings 配置到配置文件
/// </summary>
/// <param name="key">配置键名</param>
/// <param name="value">配置值</param>
/// <returns>是否保存成功</returns>
public bool SaveAppSetting(string key, string value)
{
try
{
// 1. 获取当前程序的配置文件路径(编译后的 exe.config
string configPath = AppDomain.CurrentDomain.SetupInformation.ConfigurationFile;
// 2. 加载配置文件ExeConfigurationFileMap 指定配置路径)
ExeConfigurationFileMap configFileMap = new ExeConfigurationFileMap { ExeConfigFilename = configPath };
Configuration config = ConfigurationManager.OpenMappedExeConfiguration(configFileMap, ConfigurationUserLevel.None);
// 3. 处理 appSettings 节点
if (config.AppSettings.Settings[key] == null)
{
// 键不存在 → 新增配置
config.AppSettings.Settings.Add(key, value);
}
else
{
// 键已存在 → 更新配置
config.AppSettings.Settings[key].Value = value;
}
// 4. 保存配置(重要!否则修改不生效)
config.Save(ConfigurationSaveMode.Modified);
// 5. 刷新 ConfigurationManager 缓存(可选,让后续读取能立即获取新值)
ConfigurationManager.RefreshSection("appSettings");
return true;
}
catch (Exception ex)
{
// 捕获异常(如权限不足、文件被占用等)
MessageBox.Show($"保存配置失败:{ex.Message}", "错误", MessageBoxButton.OK, MessageBoxImage.Error);
return false;
}
}
}
}